8 min read

Tankless Water Heater Not Working? Causes, Error Codes & Fixes in BC

When a tankless water heater quits, it usually tells you why. Most units put a code on the display, and the code points you to the cause. Some of those causes take thirty seconds to fix, like a gas valve someone bumped closed or a tap that isn't open far enough. Others are a job for a licensed gasfitter.

This guide walks through the common problems in the order you'd check them, using what Navien and Rinnai publish in their own owner's manuals. It also covers freezing, which matters more for tankless owners in BC than most people expect.

Start with the display

Look at the front panel or the remote controller before you touch anything else. If there's a code, write it down. It saves time whether you fix it yourself or call someone.

A reset is a fair first try. Navien's user manual says to press the Reset button (or the OK button on outdoor models with a remote) and, if that doesn't solve it, to work through the troubleshooting chart or call for service. If the same code comes back after a reset, don't keep pressing the button. A code that keeps returning means something needs fixing.

No hot water at all

If nothing comes out of the hot tap, or the water runs cold and stays cold, Navien's troubleshooting chart lists a few things to check first:

  • The shut-off valves. The hot and cold valves under the heater have to be open. If someone worked on the plumbing recently, check these first.

  • The cold water inlet filter. It's a small screen where water enters the unit. When it clogs, flow drops and the heater may not fire.

  • How far the tap is open. A tankless heater only fires once enough water is flowing through it. Navien's chart asks whether the faucet is open wide enough to draw at least 0.5 gallons per minute. The Rinnai V53e manual lists a minimum activation flow of 0.6 GPM (1.5 L/min). A barely-open tap or a low-flow fixture can fall under that.

  • Whether the unit is frozen. More on that below.

Also check the gas. Rinnai's code chart for no ignition includes making sure the gas is turned on at the water heater and at the meter (or that a propane tank isn't empty). If your other gas appliances are also off, the problem is upstream of the heater.

Hot water that comes and goes

If the water turns hot, then cold, then hot again, flow is the first suspect. Rinnai's manual says that when you're not getting hot water or the water alternates between hot and cold, it's often because the flow is below or close to the minimum. Opening the tap further should fix it in those cases.

Rinnai also suggests lowering the temperature setting if you're having trouble at higher settings. When the setting is closer to the temperature you actually use, less cold water gets mixed in at the tap and you get more flow through the heater.

A dirty inlet filter can cause the same symptom. So can scale in the heat exchanger, which is covered in our post on tankless water heater maintenance in BC.

What the common error codes mean

Codes are different from brand to brand, so check your own manual. Here's what Navien's NPN user manual and Rinnai's V53e manual say about the codes people search for most.

Navien

  • E003, ignition failure. Navien says to make sure the main gas supply valve is open and that the gas setting on the unit matches the gas you have.

  • E012, flame loss. The burner lit and then went out. Navien lists cleaning the intake air filter, checking that the power cord is properly grounded, and confirming the gas setting.

  • E016, heat exchanger overheating. Navien says to turn the system off for at least 30 minutes and restart it, clean the inlet filter, and flush the heat exchanger.

  • E110, abnormal air pressure. Make sure the vent pipe isn't blocked.

  • E760, flushing or service alarm. The unit is asking for routine service.

Rinnai

  • 10, air supply or exhaust blockage. Rinnai's first check is that nothing is blocking the inlet or exhaust. It marks the remedies for this code as licensed professional only, but you can look outside for snow or debris over the vent openings.

  • 11, no ignition. Confirm the gas is on at the heater and the meter. Beyond that, the list covers gas pressure, igniter and wiring, which is professional work.

  • 12, no flame. Similar gas checks, plus flue obstructions and power supply problems.

  • LC, scale buildup. The heat exchanger needs a flush. Rinnai notes this is the only code that lets the unit keep running. The display alternates between LC and the temperature setting and the controller keeps beeping.

Many of the codes in both manuals simply say to contact the manufacturer or a technician. Those point to failed parts like sensors, fans, gas valves and circuit boards.

Freezing is the winter problem

A tankless heater doesn't hold a tank of warm water, so there's less standing between its waterways and a cold snap. Rinnai makes this point directly in its cold weather guidance for owners.

Most units protect themselves, but only with power. Navien's manual says the freeze protection needs electricity and works as long as the unit is plugged in, even when the heater is switched off. It says not to unplug it or close the gas valve except for maintenance. Rinnai's V53e manual says freeze protection may not work if the power is out or an error stops the heater, and that a frozen unit can mean a burst heat exchanger or water lines. Both brands say freezing damage isn't covered by their warranty.

The unit's own protection doesn't cover the pipes running to and from it, either. Rinnai recommends insulating exposed hot and cold lines and keeping the vent termination and condensate drain clear of snow and ice.

If the power goes out during freezing weather, Rinnai's manual gives two options. For a short outage, turn the heater off, close the gas supply valve, and run a hot tap at about 0.1 gallons per minute, a stream about 0.2 inches (5 mm) thick. For a longer outage, drain the heater following the steps in your manual. If you think the heater is already frozen, Rinnai says not to run it. Close the gas and water valves, turn off the power, wait for it to thaw, then check the heater and pipes for leaks.

Our guide to frozen pipes and winterizing outdoor taps in BC covers the rest of the house.

What to leave to a pro

Rinnai's troubleshooting chart is blunt about it: call a licensed professional for any remedy that involves gas or electricity, or if you have any doubt about doing it yourself. That covers gas pressure, igniters, flame rods, fans, sensors and circuit boards. Rinnai also says damage from scale in the heat exchanger isn't covered by its warranty, so regular service matters.

And if you smell gas near the heater, don't troubleshoot at all. Leave the house and follow the steps in what to do if you smell gas in your BC home.

Repair or replace?

A clogged filter, a closed valve or a scaled heat exchanger is a fix. A cracked heat exchanger or a unit that keeps throwing new part failures is a different conversation. If you're weighing a new unit, our tankless vs. tank comparison lays out the trade-offs.

Get your hot water back

Ark Plumbing & Heating's licensed plumbers and gasfitters handle tankless water heater service and repair across the Lower Mainland, including error codes, lukewarm water and units that shut off. Write down the code and the brand, then call 604-441-3411 or send us a message.

Article details

Date

Author

Noah Debebe

Need a hand?

Have a question or need help planning the next step? We’re here to help.

Get in touch

Need a plumber fast?

Someone from our team will be ready to answer your call!

Need a plumber fast?

Someone from our team will be ready to answer your call!

Need a plumber fast?

Someone from our team will be ready to answer your call!